Analisa Pengukuran Kualitas Daya dan Pengaruhnya terhadap Performa Transformator Distribusi 1600 kVA Menggunakan Power Quality Analyzer Hioki PQ3198 di PT.Salim Ivomas Pratama Tbk

Authors

  • Novita Vadina Marta Ria Universitas Negeri Malang
  • Royb Fathkur Rizal Universitas Negeri Malang

DOI:

https://doi.org/10.31004/riggs.v5i1.8155

Keywords:

Power Quality, Distributions Transformers, Harmonics, Measurement, Systems

Abstract

Power quality is a crucial factor affecting the performance and reliability of distribution transformers in industrial power systems. Deviations such as harmonic distortion, load imbalance, voltage fluctuations, and transient disturbances can lead to increased losses, overheating, and reduced transformer insulation life. This study aims to analyze power quality measurements and their impact on the performance of a 1600 kVA distribution transformer using the Hioki PQ3198 Power Quality Analyzer at PT. Salim Ivomas Pratama Tbk. Real-time measurements were conducted on parameters including voltage (average 396-406 V), current (460-1060 A), frequency (50 Hz), power factor, and harmonic distortion (THD voltage <8%, THD current 6-8%) in a three-phase system with ABB Dyn5 specifications, ONAN cooling, and 5.9% impedance. A quantitative descriptive method with field data analysis revealed stable voltage and frequency with no significant voltage dips/swells, and voltage harmonics complying with IEEE 519 standards, although current harmonics were relatively high due to non-linear loads like inverters. The evaluation results indicate relatively good power quality, with optimal operational efficiency and low risk to equipment degradation, supported by normal transformer oil DGA analysis (TDCG 197 ppm). However, elevated current THD poses potential efficiency losses and accelerated aging, recommending harmonic filters, periodic monitoring, and load balancing to enhance distribution system reliability. This research provides insights into the relationship between power quality and transformer performance, supporting preventive maintenance in industrial installations.

Downloads

Download data is not yet available.

References

G. Samiaji et al., “BERDASARKAN HARMONISA PADA MOTOR LISTRIK,” vol. 12, no. 3, pp. 2735–2743, 2024.

M. S. Seddik, M. B. Eteiba, and J. Shazly, “Evaluating the Harmonic Effects on the Thermal Performance of a Power Transformer,” 2024.

S. Kualitas, D. Listrik, and P. Quality, “Studi kualitas daya listrik (power quality) di bangunan gedung xyz,” vol. 13, no. 2, 2025.

L. M. Parera, M. Jamlaay, and A. F. Lokollo, “Analisis Kualitas Daya Listrik Pembangkit Listrik Tenaga Surya Mini-Grid,” pp. 150–161.

R. N. D. Nike, A. Kusumawardana, R. F. Rizal, and ..., “A Perbaikan Kualitas Daya Listrik Pemakaian Sendiri PLTA Wlingi Melalui Implementasi Kapasitor Bank dan Filter LC: Studi Simulasi Peningkatan Faktor Daya dan …,” Orbith Maj. …, vol. 21, no. 2, pp. 89–94, 2025, [Online]. Available: https://jurnal.polines.ac.id/index.php/orbith/article/view/6660%0Ahttps://jurnal.polines.ac.id/index.php/orbith/article/download/6660/110029

P. H. T. Hutabarat and M. F. Zambak, “Prediction of Electricity Need for The PLN Area in Parapat Simalungun City Until 2024,” vol. 5, no. 2, 2024.

M. A. Rizkiawan, E. Kurniawan, and H. Ramza, “Analisis Kualitas Daya Menggunakan Filter Daya Harmonik Aktif Berbasis PV,” vol. 6, pp. 154–163, 2024.

I. Isdawimah, “DESAIN SISTEM MONITORING KUALITAS DAYA LISTRIK SECARA ONLINE kualitas yang baik dapat dilakukan dengan dilakukan bila diketahui nilai besaran yang dapat diakses melalui internet , tetapi Pengubahan bentuk gelombang dari pengubahan bentuk gelombang lain ya,” vol. 14, no. 2, 2015.

N. F. Indah, H. S. T. Munnik, H. S. T. Munnik, U. Dirgantara, and M. Suryadarma, “Analisis Dampak Arus Harmonisa Terhadap Kerugian Dan Penuruan Daya Mampu ( Derating ) Pada Trafo 167 Mva Dengan Metode Matriks Spektrum Arus Harmonisa Di Gistet Cawang,” vol. 1, no. 1, pp. 1–12, 2025.

M. N. Hidayat, S. Meliala, and R. Putri, “ANALISA RUGI – RUGI DAYA AKIBAT HARMONISA PADA SISTEM DISTRIBUSI 20 KV DENGAN PENGGUNAAN SINGLE TUNED FILTER PENYULANG LG -02 PT PLN ULP LANCANG GARAM,” vol. 14, pp. 58–64, 2025.

E. Sumarno and E. Sumarno, “Analisis Distorsi Harmonisa Kualitas Daya Listrik Tiga Fasa Panel Distribusi Menggunakan Power Quality Analyzer di Rumah Sakit X,” vol. 3, no. 2, pp. 147–155, 2025.

H. Chen, J. Wang, H. Hu, and Y. Huang, “Assessment of voltage harmonics ’ impact on the maximum load capacity of the power supply transformer for the LHCD system,” Sci. Rep., pp. 1–8, 2024, doi: 10.1038/s41598-024-56366-x.

V. Yarlagadda, G. Ambati, B. Devulal, S. R. Jalluri, C. S. Kumar, and N. Alekhya, “INTELLIGENT SYSTEMS AND APPLICATIONS IN ENGINEERING Power Quality Improvement of Wind Power Plant using STATCOM and Harmonic Filters,” 2024.

M. D. Borrás, J. C. Bravo, J. C. Montaño, and S. Member, “Disturbance Ratio for Optimal Multi-Event Classification in Power Distribution Networks,” no. c, 2016.

H. M. Naibaho, A. Warsito, and S. Handoko, “PENINGKATAN KUALITAS DAYA LISTRIK DENGAN MENGGUNAKAN BANK KAPASITOR DAN FILTER PADA KAJI STATION PT . MEDCO E & P,” pp. 3–10, 1992.

Downloads

Published

29-04-2026

How to Cite

[1]
N. V. M. Ria and R. F. Rizal, “Analisa Pengukuran Kualitas Daya dan Pengaruhnya terhadap Performa Transformator Distribusi 1600 kVA Menggunakan Power Quality Analyzer Hioki PQ3198 di PT.Salim Ivomas Pratama Tbk”, RIGGS, vol. 5, no. 1, pp. 15278–15290, Apr. 2026.